Dampproofing is a coating that slows soil moisture through a below-grade foundation wall, and waterproofing is a membrane that resists water under pressure. 2021 IRC Section R406.1 requires dampproofing on basement walls, and Section R406.2 requires waterproofing where a high water table or severe soil-water condition is known.

Both treatments go on the outside of the foundation wall before backfill, and both run from finished grade down to near the footing. The difference is how much water they are built to stop. Dampproofing handles normal soil dampness. Waterproofing is for sites where groundwater pushes against the wall. This page sets out what the 2021 International Residential Code (IRC) requires for each, plus the foundation drain that works alongside them.

Key facts

  • Foundation walls that retain earth and enclose interior spaces and floors below grade must be dampproofed unless Section R406.2 requires waterproofing (2021 IRC Section R406.1).
  • Dampproofing runs from finished grade to the higher of the top of the footing or 6 inches below the top of the basement floor (2021 IRC Section R406.1).
  • Masonry foundation walls need not less than 3/8 inch of portland cement parging on the exterior before dampproofing (2021 IRC Section R406.1).
  • Waterproofing is required where a high water table or other severe soil-water conditions are known to exist (2021 IRC Section R406.2).
  • Gravel or crushed stone foundation drains must extend not less than 1 foot beyond the outside edge of the footing and 6 inches above its top (2021 IRC Section R405.1).

What is the difference between dampproofing and waterproofing?

Dampproofing resists moisture moving through the wall by capillary action, and waterproofing resists liquid water under hydrostatic pressure. In code terms the difference is the site: Section R406.1 is the default for basement walls, and Section R406.2 takes over where severe soil-water conditions are known.

DampproofingWaterproofing
2021 IRC sectionR406.1R406.2
When requiredWalls that retain earth and enclose interior spaces and floors below gradeSame walls, where a high water table or other severe soil-water condition is known
Height coveredFinished grade to the higher of the footing top or 6 inches below the basement floor topSame as dampproofing
Typical materialsBituminous coating, acrylic modified cement, surface-bonding cementHot-mopped felts, roll roofing, polymer-modified asphalt, polymer cement, synthetic rubber
JointsNo lap ruleMembrane joints lapped and sealed with compatible adhesive

Every waterproofing material in Section R406.2 also counts as dampproofing, so a builder can always go up a level. Going the other way is not allowed: a dampproofing coat does not satisfy a waterproofing requirement.

Which foundation walls need dampproofing?

Dampproofing is required on concrete and masonry foundation walls that retain earth and enclose interior spaces and floors below grade. A basement is the clear case. For a shorter stem wall or crawl space wall, check with the building official whether it encloses interior space below grade in the sense of Section R406.1.

The extent is fixed. Coverage starts at finished grade and continues down to whichever is higher: the top of the footing, or a point 6 inches below the top of the basement floor. On a basement with a thick slab sitting on the footing, the floor line usually controls. On a basement with the slab well above the footing, the footing top controls.

How do you dampproof a concrete foundation wall?

A poured concrete wall is dampproofed by applying any one of the dampproofing materials listed in Section R406.1, or any one of the waterproofing materials listed in Section R406.2, to the exterior of the wall. No parging is needed on cast concrete.

The dampproofing options are:

  1. Bituminous coating.
  2. Three pounds per square yard of acrylic modified cement.
  3. A 1/8-inch coat of surface-bonding cement complying with ASTM C887.
  4. Any material permitted for waterproofing in Section R406.2.
  5. Other approved methods or materials.

Spray-applied bituminous coating is the common choice on new poured walls because it goes on fast before backfill.

Does a block foundation need parging?

Yes. Masonry foundation walls must have not less than 3/8 inch of portland cement parging applied to the exterior, and the parging is then dampproofed with one of the five options above.

Parging fills the mortar joints and the texture of the block so the coating has a continuous surface. The exception in Section R406.1 drops the parging only where a material is approved for direct application to the masonry. For the structural side of block walls, see the concrete block foundation guide.

When is foundation waterproofing required?

Waterproofing is required where a high water table or other severe soil-water conditions are known to exist. The building official or a soils report normally flags those sites.

Section R406.2 lists six waterproofing systems:

2021 IRC Section R406.2, approved foundation waterproofing materials.

OptionMaterial
1Two-ply hot-mopped felts
255-pound roll roofing
340-mil polymer-modified asphalt
460-mil flexible polymer cement
51/8-inch cement-based, fiber-reinforced, waterproof coating
660-mil solvent-free liquid-applied synthetic rubber

All joints in membrane waterproofing must be lapped and sealed with an adhesive compatible with the membrane. Waterproofing covers the same height as dampproofing: finished grade down to the higher of the footing top or 6 inches below the top of the basement floor.

ICF walls

Insulated concrete form walls need care with solvents. The exception in Section R406.2 bans organic-solvent-based products, such as hydrocarbons, chlorinated hydrocarbons, ketones and esters, on ICF walls with expanded polystyrene forms. Plastic roofing cements, acrylic coatings, latex coatings, mortars and pargings are permitted. Cold-setting asphalt or hot asphalt must conform to Type C of ASTM D449, and hot asphalt must be applied at less than 200 degrees F. The ICF foundation guide covers the rest of the system.

Wood and precast foundations

Wood and precast foundations have their own rules in the same section:

  • Permanent wood foundations follow Section R406.3: sealed plywood joints, a 6-mil polyethylene film over the below-grade wall, porous fill and backfill. The permanent wood foundation guide walks through each step.
  • Precast concrete foundations are dampproofed under Section R406.1 unless waterproofing is required (Section R406.4). Panel joints must be sealed full height with a sealant meeting ASTM C920, Type S or M, Grade NS, Class 25, Use NT, M or A, installed to the manufacturer's instructions (Section R406.4.1).

Is a foundation drain required?

A foundation drain is required around concrete or masonry foundations that retain earth and enclose habitable or usable spaces below grade (Section R405.1). Dampproofing slows moisture through the wall, and the drain keeps water from building up against it in the first place.

Section R405.1 sets the details:

  • Drainage tiles, gravel or crushed stone drains, perforated pipe or other approved systems go at or below the top of the footing, or below the bottom of the slab.
  • The drain discharges by gravity or mechanical means into an approved drainage system.
  • Gravel or crushed stone drains extend not less than 1 foot beyond the outside edge of the footing and 6 inches above the top of the footing, covered with an approved filter membrane.
  • Drain tile or perforated pipe sits on not less than 2 inches of washed gravel or crushed rock and is covered with not less than 6 inches of the same material.

The exception covers foundations on well-drained ground or sand-gravel mixture soils, classed as Group I in Table R405.1. Group I includes the GW, GP, SW, SP, GM and SM soils. Basement window wells tie into this same system; see egress window requirements for the area well rule.

Where this fits in a basement build

Dampproofing, drainage and backfill happen before the floor framing goes on top of the wall. Once the wall is dry and backfilled, the sill plate and floor system follow. Inside the basement, wood in contact with concrete needs its own moisture protection, covered in how to frame a basement wall.

These are the prescriptive minimums. The adopted code edition and local amendments govern, and proprietary membranes and coatings follow the manufacturer's instructions for thickness, primers and laps.

Summary

Basement and other below-grade foundation walls that retain earth must be dampproofed under 2021 IRC Section R406.1, from finished grade to the higher of the footing top or 6 inches below the basement floor. Masonry walls need 3/8-inch parging first. Where a high water table or severe soil-water condition is known, Section R406.2 requires one of six waterproofing systems instead, and Section R405.1 adds a foundation drain unless the soil is Group I.

Framing Plan is a preliminary drawing aid that draws joist layouts, beams and openings and exports PNG, PDF and DXF. It does not specify foundation coatings and works in millimeters, so put the dampproofing and drain notes on your foundation section. Open the framing studio to lay out the floor that sits on the wall.