A lintel is the horizontal member that carries masonry over a door or window opening. For brick or stone veneer, 2021 IRC Section R703.8.3 requires a noncombustible lintel with at least 4 inches of bearing, sized from the steel angle spans in Table R703.8.3.1.

In a house, the word lintel almost always means the steel angle you see tucked under the brick above a window. It holds up the veneer only. The wood framing behind it has its own header that carries the floor and roof. This page covers the lintel side of that pair, using the 2021 International Residential Code (IRC). For the wood side, see the header size chart.

Key facts

  • Masonry veneer may not support any vertical load other than the dead load of the veneer above (2021 IRC Section R703.8.3).
  • Veneer above an opening must sit on a lintel of noncombustible material with a length of bearing of not less than 4 inches (2021 IRC Section R703.8.3).
  • With no story above, a 4 x 3 x 1/4 inch steel angle may span up to 8 feet 0 inches (2021 IRC Table R703.8.3.1).
  • The long leg of a steel angle lintel must be placed vertically (2021 IRC Table R703.8.3.1, footnote a).
  • Openings up to 18 feet 3 inches are allowed with the extra joint reinforcement and shoring in 2021 IRC Section R703.8.3.2.
  • Steel lintels must be shop coated with rust-inhibitive paint unless the steel is corrosion resistant or coated for corrosion resistance (2021 IRC Section R703.8.3).

What is a lintel?

A lintel is a beam over an opening in a masonry wall or masonry veneer. It catches the brick, block or stone above the opening and sends that weight to the masonry on each side.

The IRC recognizes several kinds. Section R606.10 says masonry over openings in a masonry wall shall be supported by steel lintels, reinforced concrete or masonry lintels, or masonry arches, designed to support the load imposed. For veneer over a wood or steel stud wall, Section R703.8.3 adds a prescriptive table so a typical house opening can be sized without an engineer.

Common lintel types in residential work:

Lintel typeWhere you see it2021 IRC reference
Steel angle (loose lintel)Brick or stone veneer over windows and doorsR703.8.3, Table R703.8.3.1
Reinforced masonry lintelBrick or block courses with bars and groutTable R703.8.3.1, footnote b
Reinforced concrete lintelConcrete block and solid masonry wallsR606.10
Masonry archSolid masonry wallsR606.10

What is the difference between a lintel and a header?

A header carries structural loads in a framed wall, and a lintel carries masonry. They often sit a few inches apart in the same opening.

On a brick-veneer house the stud wall has a wood header, sized from 2021 IRC Section R602.7 and Tables R602.7(1) and R602.7(2), that carries the floor or roof above. Outside the sheathing and air space, a steel angle carries only the brick. Section R703.8.3 is explicit that the veneer may not carry any vertical load other than its own dead weight, so the lintel must never be used to pick up framing. If you are laying out the framing for a window in a veneered wall, frame the rough opening as described in how to frame a window and treat the lintel as a separate item on the elevation.

Steel lintel span chart for brick veneer

Table R703.8.3.1 gives the allowable span for each steel angle size, based on how many stories sit above the opening. The last column gives the alternative: the number of 1/2-inch reinforcing bars for a reinforced masonry lintel over the same opening.

2021 IRC Table R703.8.3.1, allowable spans for lintels supporting masonry veneer (feet-inches). Long leg vertical. Steel members listed are typical examples.

Steel angle size (inches)No story aboveOne story aboveTwo stories aboveNo. of 1/2-inch bars in reinforced lintel
3 x 3 x 1/46-04-63-01
4 x 3 x 1/48-06-04-61
5 x 3-1/2 x 5/1610-08-06-02
6 x 3-1/2 x 5/1614-09-67-02
2-6 x 3-1/2 x 5/1620-012-09-64

The last row is printed in the table as 2-6 x 3-1/2 x 5/16, the IRC notation for a pair of 6 x 3-1/2 x 5/16 angles.

Footnotes that change the answer

  • a. The long leg of the angle goes in a vertical position. A 4 x 3 angle is installed with the 4-inch leg standing up.
  • b. A reinforced lintel must be not less than 8 inches deep, all cells of hollow masonry lintels must be grouted solid, and the bars must extend not less than 8 inches into the support.
  • c. The steel members listed are adequate typical examples. Other steel members meeting structural design requirements may be used.
  • d. Either the steel angle or the reinforced lintel has to span the opening. You do not need both.

How to read the chart

"Stories above" counts the veneer that sits over the opening, not the framing. A first-floor window under a full second story of brick is "one story above." A window in the top story, with only the gable or a short run of brick over it, is "no story above." Pick the row whose span meets or exceeds the opening width. A 6-foot first-floor window under one story of brick needs at least the 4 x 3 x 1/4 angle (6-0 allowable), while the same window in the top story could use a 3 x 3 x 1/4 angle (6-0 allowable).

How much bearing does a lintel need?

A veneer lintel needs not less than 4 inches of bearing at each end under Section R703.8.3. That means the lintel is longer than the opening by at least 8 inches in total.

Bearing is measured on the masonry beside the opening. On a drawing, dimension the lintel length, not just the opening, so the mason and the inspector can check it. Reinforced masonry lintels have a second check from footnote b: the bars must run not less than 8 inches into the support.

What is the maximum span for a brick lintel?

The prescriptive maximum is 18 feet 3 inches under Section R703.8.3.2, which allows wider openings than the table when the veneer is built to Figure R703.8.3.2 and four conditions are met:

  1. Not less than 18 inches of masonry veneer on each side of the opening.
  2. A steel angle of not less than 5 by 3-1/2 by 5/16 inch above the opening, shored for not less than 7 days after installation.
  3. Double-wire joint reinforcement extending 12 inches beyond each side of the opening, with lap splices of not less than 12 inches. Use either 3/16-inch-diameter wire in the first two bed joints above the opening, or 9 gauge (0.144 inch) wire in the first three bed joints.
  4. A height of masonry veneer above the opening that follows Table R703.8.3.2.

2021 IRC Table R703.8.3.2, height of masonry veneer above opening.

Minimum height of veneer above opening (inches)Maximum height of veneer above opening (feet)
13Less than 5
245 to less than 12
6012 to the height above support allowed by Section R703.8

This path is typical for wide garage door openings in brick. Anything outside the table or Section R703.8.3.2 needs a design.

Do steel lintels need to be painted?

Yes. Section R703.8.3 requires steel lintels to be shop coated with a rust-inhibitive paint, unless the lintel is made of corrosion-resistant steel or steel treated with coatings that provide corrosion resistance. Galvanized angles are common for that reason.

Water management at the lintel matters just as much. Section R703.8.5 requires flashing at points of support, including lintels, and Section R703.8.6 requires weepholes immediately above that flashing, not less than 3/16 inch in diameter and at a maximum spacing of 33 inches on center. The brick ties guide covers tie spacing, including the extra ties Section R703.8.4.1.1 requires around openings larger than 16 inches in either dimension.

Lintels in solid masonry and block walls

In a structural masonry wall, such as a concrete block foundation or a block house wall, the lintel carries real loads, not just veneer. Section R606.10 requires those lintels to be designed to support the load imposed, so Table R703.8.3.1 does not apply. Precast concrete lintels and bond-beam block lintels are sized from the manufacturer's tables or by a designer. Section R606.8 also requires a noncombustible lintel over any chase or recess in a masonry wall wider than 12 inches.

Showing lintels on a framing plan

A framing plan shows the wood header, and the elevation or wall section shows the lintel. A clear set does both:

  • Label the header on the plan with size and plies, as described in the header size chart.
  • Note the lintel on the elevation, for example L4x3x1/4 GALV, 4" MIN BRG EA END.
  • Show the flashing and weeps at the lintel in the wall section.

The house framing diagram shows where headers, jack studs and king studs sit, and how to frame a door covers the same opening logic for doors in a veneered wall.

Limits of this chart

Table R703.8.3.1 covers masonry veneer only, within the veneer limits of Section R703.8. Structural masonry, stone heavier than the veneer limits, and openings outside the table need a design. The adopted code edition and local amendments govern, and proprietary lintels follow the manufacturer's published tables. The full code text is on ICC's 2021 IRC page.

Summary

A lintel carries masonry over an opening. Veneer lintels must be noncombustible, bear at least 4 inches at each end, and follow the steel angle spans in 2021 IRC Table R703.8.3.1, with the long leg vertical. Wider openings up to 18 feet 3 inches use Section R703.8.3.2, and the framing behind the veneer still needs its own header.

Framing Plan is a preliminary drawing aid that draws joist layouts, beams and openings and exports PNG, PDF and DXF. It does not size lintels or headers and works in millimeters, so add the lintel callouts from this chart to your elevations. Open the framing studio to lay out the openings.